Simplify cloud operations and optimize costs with confidence.
Recently active
Nutanix guest tools (NGT) is a software bundle that you can install in a guest virtual machine (Microsoft Windows or Linux) to enable the advanced functionality provided by Nutanix. Nutanix Guest Tools enables the VM to CVM communication and sometimes we might encounter the NGT Services to be falling with the signature guiding towards SSL error. So how do I identify if I’m facing a similar issue and resolve it? You can refer to the KB-3868 for guidance regarding which log file to check and which error trace is matching the issue. After confirming that you’re encountering the same issue, you can proceed with the solution mentioned in the knowledge base article. Want to know more about NGT and it’s configuration? Give the following document a coffee readNGT Guide Prism
Security is the backbone of every infrastructure and Nutanix Prism gives you an option to upload an SSL certificate to establish secure communication with the cluster. Every AOS includes a self-signed SSL certificate by default to enable secure communication with a cluster.How I create my own-self signed certificates? The following Knowledge Base article will guide you with the process of generating your own self-signed certificates.KB- 1537 How can I upload or replace custom or self-signed certificates to establish secure communication? The following documentation will guide you with the process to upload the certificates using Prism GUI Prism Certificate Management
Handling a large infrastructure is tough and Prism Central is a tool to manage a large number of clusters with ease. Let’s say you’re handling 10 clusters and want to have an image in all 10 clusters to be readily available.Do we need to manually add images to each and every cluster? Prism Central 5.5 and above includes a global image service that allows you to add (upload) images through Prism Central by using the v3 API. Need info on how to browse and add images to Prism Central? Give the following documentation guide a read. Prism Central Images I uploaded an image using Prism Central but can’t view it? There might be a situation in which you have created an image but you might not see the image in the list of available images when you are creating a VM. Try going through the following knowledge base articleKB-4892 Want to know more about Prism Central? Try giving the official documentation a coffee readPrism Central
We normally keep a handful of template VM’s with different type of OS that are updated and “ready to go” and use these for global automation when deploying new machines. I would like a way to deploy these templates as qcow2 images globally using the Prism Central image management. After a template VM are updated, I would like to automate them beeing converted to qcow2 images (already got this working with “qemu-img convert” command) and then import the qcow2 image to the Image repository in Prism Central to be distributed to all sites. The last step I have not managed to figure out how to do. Obviously I need some kind of API or CLI to automate this but all I find is how to do this using the GUI in PC. Did I miss something?
Registered your Prism Element to a Prism Central, but now want to unregister the PE from the Prism Central and confused regarding the steps! Why would anyone like to unregister a cluster?The following are the reasons when you might want to unregister a cluster from prism central and perform a clean-up. Prism Central functionality is being evaluated but you do not plan to use the functionality. You manage your cluster or clusters using a different Prism Central instance. The Prism Central that your cluster was previously registered to has been destroyed or decommissioned.Unregistering a cluster through Prism GUI is no longer available and now you’ll be wondering the “WHY SO??”Well we all make mistakes and accidentally unregistering a cluster can be a big risk, so we need to mitigate the riskSo what’s the process to unregister a cluster? Before answering the question, let’s take note of one pointAfter the force cleanup process mentioned in the below mentioned KB is followed, all PC-PE re
I am looking to monitor performance of my Volume Groups during third party backups. I am using a 3rd party vendor and when the backup starts, Volume Groups are created for the snapshotted disks. I want to create a metric/entity chart but want to see if there is a way to create one for ALL Volume Groups so when a new one is created, it is included into the chart. Currently I can only see creating it while one exists but I want to monitor it from start to finish periodically.
Every infrastructure admin knows the importance of the correct time zone to be configured in architecture otherwise, administration jobs and log analysis between different components is nothing but a nightmare to go through.So do we have an option to change the time zone of the CVM in a Nutanix cluster?Yes, we do!Give the following KB a read to know the procedure to change the time-zone of the CVMKB-1050Nutanix Cluster Check(NCC) also have a check which confirms whether the CVMs in a Prism Element are in the time-zoneFor more information on the checkKB-2044Confused regarding the procedure or have further queries?Drop a comment and let’s start a conversation.
Hello, I've been looking relatively hard for a comprised list of STS and LTS release dates and a indexed link to the readme's for those releases and perhaps the CVE's addressed in those patches. Seems like it would be easy to find but I'm struggling.
LifeCycle Manager (LCM) is the 1-click upgrade process for firmware and software on Nutanix clusters. This feature can be accessed through the Prism UI. LCM Provides Two Operations: 1. Inventory: Detects what can be managed on a cluster. 2. Update: Performs an update to a certain version.So what happens before an update?LCM runs a set of pre-defined checks, pre-checks to confirm and validate your cluster health and sanity. If any checks fail, it shows you as an error and advises you to fix the issue before going ahead with the upgrade.So what are those pre-checks?Do we have a list and recommendation if we encountered a pre-check failure before the upgrade or if we want to the know the list of complete pre-checks to proactively make our cluster ready for an upgrade? Of course, we have a list of pre-checks and the recommended KBs to help you resolve the issue and go ahead with the upgrade smoothly and efficiently.Try going through the following KB to get an idea about the pre-ch
Sometimes it is necessary to delete and re-deploy Prism Central (PC) VM. Instances may include errors that occurred during PC deployment or when PC version deployed is outside of Software Product Interoperability matrix. Starting with version 5.5, Prism Central becomes the primary management plane and houses features like SSP, Calm, RBAC, Microsegmentation, etc. Therefore it is important to follow the recommended process when deleting PC VM: Identify the cluster on which the Prism Central VM that you wish to delete has been deployed. Copy the Prism Central VM name from this cluster. Unregister and clean up all clusters registered to Prism Central. Check if all clusters have been unregistered from Prism Central by executing the following command from any CVM in each cluster. Delete the Prism Central VM. Check if the Prism Central VM has been deleted by logging into the cluster's Prism Element UI and browsing the VM section. For detailed instruction please refer to KB-6274 How to delete
Using less storage for more data is awesome. After all storage does not come cheap. Files Servers often become black holes of storage space in the environment where they consume space rapidly and ever increasingly. While using deduplication on Nutanix Files container might seem like a good idea at first, unfortunately, it is not recommended.Excerpt from Nutanix Files Tech Note:Every file server maps one-to-one to a container. This mapping allows you to manage compression and erasure coding individually for each file server deployed. Inline compression and erasure coding are turned on by default to save capacity. Deduplication is not recommended. [...]From Files 3.6 onward, you can control compression on a share-by-share basis. When you create a share, compression is enabled by default. This is backed up by NCC health check file_server_container_check which fails if deduplication is enabled on a container used by Nutanix Files.As always, you can bookmark useful KBs by hitting that star
In our previous post, we explored “where are vdisks stored for AHV VMs and how to access or download them”. In this post, we will briefly go through the AOS Image service, which contains all ISO images, disk images etc.What is AOS Image Service:The image service feature enables you to import the images (ISOs, disk images, or any images which are supported in ESXi or Hyper-V format) directly into virtualisation management.The raw, vhd, vmdk, vdi, iso, qcow2 disk formats are supported.You can import images from http or NFS source URL. You can use this feature to create disks for a VM from images (images that are stored in the image library or repository) and also an option to clone from an image. You must install virtIO drivers on the image prior to importing these images into the image library.By creating an image of an existing bootable disk or a non-bootable disk, we are publishing it in the AOS image service across the cluster. Any Cluster Admin can use this image to spin up further
Hi community I am planning an upgrade of our Hypervisor of ESXi from VMware ESXi, 6.5.0, 8294253 to 6.5 U3 Latest build. Just wanted to get some feedback whether the process I have would be the correct one? first time we plan to use the one click upgrade process! We have 2 clusters, a production and DR cluster. We do use Data protection and Async DR and I believe that the target Async environment needs to be updated first which is the preferred option anyway. This is the approach I was going to take. Any feedback on this would be great. Prism Central SpecificNCC (already upgraded to latest 3.9.2.1 version)Prism Central from 5.10.4 to 5.11.1.1We use vCentre VCSA 6.5, we plan to also upgrade this to later patching level. This will be done separately. Prism Element (each cluster)NCC (already upgraded to latest 3.9.2.1 version)Install AOS 5.10.4.1 LTS to 5.10.8 LTS. We wish to stay on a LTS release, is this the latest one for LTS.? 5.11.1.2 is available for us to install but I think this
Is there a way to unack and unresolve alarms that have been marked wrongly or needs to be passed between shifts and operators?
We all have a safe number in our head when it comes to storage utilization rate. Depending on professional background the answer will vary between 75%-85%. Sure, would that be of total space? Total space per node? Let’s take a look.This example assumes a five-node cluster consisting of the following. One (1) four-node Model NX-3050 The physical storage capacity available is 4.48 TBs per node, or 17.92 TBs total One (1) node of a Model NX-6060 The physical storage capacity is 13.91 TBs per node The total physical storage capacity available to use on this cluster is: (4 x 4.48) + 13.91 = 31.83 TBT = 31.83 N1 = 13.91 N2 = 4.48The recommended maximum utilization of this cluster when using Replication Factor of 2M = 0.9 x (T - N1 ) 0.9 x ( 31.83 - 13.91) = 16.128 TBThe recommended maximum utilization of this cluster when using Replication Factor of 3M = 0.9 x (T - [N1 + N2]) 0.9 x (31.83 - [13.91 + 4.48]) = 12.09 TBNote: The values for storage used in the example are not representative of
Hi all, I am working on a DevOps platform for a client and considering recommending Calm to automate the provision of TeamCity builds if the build queue meets a condition (i.e. if 15 builds in queue then spin up 5 build agents and add them to the pool). Has anyone done this with Calm ?
Nutanix Calm allows you to seamlessly select, provision, and manage your business applications across your infrastructure for both the private and public clouds. Nutanix Calm provides App lifecycle, monitoring and remediation to manage your heterogeneous infrastructure, for example, VMs or bare-metal servers. Nutanix Calm 2.7.1.3 Release Notes Nutanix Calm Download 2.7.1.3 Nutanix Calm Administration and Operations Guide 2.7.1 This release includes the following new and updated features: Multi-Cluster Deployment in CalmYou can map one or more AHV clusters to a project and whitelist subnets from the selected clusters. This gives you flexibility to manage application workloads across AHV clusters within a blueprint.Support for Single VM Blueprint on Public Cloud ProvidersSingle VM blueprint is a framework that you can use to quickly create an instance, provision, and launch applications requiring only a single VM across all providers configured. We have added support for public cloud pro
We had an issue last evening where one of our nodes decided to take a dive. (Uncorrectable memory in one of the DIMMs).Anyways, I happened to check my email this morning and was like wonderful. So I hopped on to check things out. Turns out the node is indeed unable to boot. So, opened a case. A speedy response - yay!However, I am wondering what type of alerts that are automatically sent to nos-alerts trigger a support case? One would think that a node down and the cluster in HA state would trigger a support case… so I checked the postfix logs and see that an email was sent when everything occurred last evening… which leads me to ask, “What exactly will trigger an alert on the support end if this particular issue didn’t?”Thanks for any insight. Loving Nutanix so far.
Hi, Does anyone know what cause the "Admin User API Authentication Check" result with "Warning" ? I have not clue, please help. Thank you,
You have multiple storage containers in your AHV Nutanix cluster(Nutanix recommends having a single container to simplify operations) and have a need to move a User VM from one storage container to another but confused regarding the process.Let us guide you by giving a brief summary of the operation you need to perform.If you’re using AOS 5.5.X and 5.6.X and cluster is managed by Prism Central consider upgrading or following the steps mentioned in KB 3577 to download VM disk file from source container to workstation and then upload to the destination container.For other AOS version, the following steps would help. Find the VM disk files using the following command from any CVMnutanix@cvm:~$ acli vm.get <VM name> include_vmdisk_paths=1 | grep -E 'disk_list|vmdisk_nfs_path|vmdisk_size|vmdisk_uuid' This will give us the VMdisk UUD and container path. You’ll need this when creating an image for the vmdisk in the next step. Power of the VM and create a new image of each vmdisk . Cr
NCC 3.8.0 Known Issue:We have a known issue in NCC 3.8.0 for a False Power Supply Alert If you receive the following alert in Prism, please upgrade to NCC 3.9.0 or higher to resolve this issue. ID : dbc12345-e30b-40d4-aecd-a0358307363a Message : In block 16SM12345678, mixed types of PSUs found = P, PWS-1K02A-1R Severity : kInfo Title : In block 16SM12345678, mixed types of PSUs found Created On : Mon Jul 15 22:35:36 PDT 2019 Acknowledged : false Acknowledged By : Acknowledged On : Resolved : false Auto Resolved : false Resolved By : Resolved On : Entities On : cluster:dbc12345-e30b-40d4-aecd-a0358307363a::1234567 The latest NCC version can be located from the following link. Tools & Firmware
How do clean old Prism Alerts. Within Webconsole Resolve and Acknowlege doesnt clean old alerts. Any command would helpful. Thanks,
I want to pull alerts from my cluster using ncli. however, the alert message gets truncated. here is an example: code:ncli> alerts ls max-alerts=1 ID : XXXXXXXXXXXXXXXXXXXXXXXXXXXXXX Message : Unable to locate VM(s) VM1, VM2, VM3, VM4, VM5, VM6, VM7, VM8, VM9, VM10, VM11, VM12, VM13, VM15, V... protected by protection domain 'PDgroup2'. Notice the truncated portion with '...'. Is there a switch i can send with ncli to prevent that truncation?
I have installed Prism Cental 4.6.0.1 and Acropolis 4.6.0.1. Now I tried to register my Nutanix Cluster to Prism Central. I entered the admin credentials in the registration form. But I got an error "Failed to register to Prism Central: HTTP 403 forbidden". Any hints? best regards, arno
We would like to use Syslog-NG to forward syslogs to our syslog server. Could you please confirm if Nutanix Support Syslog-NG (I'm aware that Nutanix Supports rsyslog) Thanks, Best, Shan
Already have an account? Login
No account yet? Create an account
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.