We’ve noticed that after updating clusters to AOS 5.20.3.5 LTS, we’re unable to launch those clusters from PC. PE seems to still be fine. Anyone run into this?

Best answer by sdk404

Got it!

Poked around some today. The various version folders on the PC nodes were missing the ‘console’ folder. KB 11663 gives a command to run to manually extract this. Once I did that on all the PC nodes, was again able to launch PE from PC.

View original
Did this topic help you find an answer to your question?
This topic has been closed for comments

13 replies

  • Adventurer
  • 4 replies
  • April 21, 2022

Hi, has the PC also been updated to the latest release?


Forum|alt.badge.img
  • Author
  • Adventurer
  • 8 replies
  • April 21, 2022

yes. It only appears to be affecting clusters that we’ve updated to 5.20.3.5. We have one newer one that shipped with 6.x, and it was ok after the update.


  • Voyager
  • 1 reply
  • April 21, 2022

I experienced similar issues to this after upgrading PC, and discovered the CVM was out of disk space. Maybe run a “df - h” command if you can get to the CVMs and check the usage on the /home dir.


Forum|alt.badge.img
  • Author
  • Adventurer
  • 8 replies
  • April 21, 2022

Nope, not seeing high disk usage on the CVMs.


  • Adventurer
  • 4 replies
  • April 22, 2022

Rather basic but have you tried rebooting the PC as well? If that doesn’t help I think you’ll need to reach out to support, see if it’s a known bug with the latest release of 5.20.x


Forum|alt.badge.img
  • Author
  • Adventurer
  • 8 replies
  • April 22, 2022

PC reboot unfortunately did not clear the issue. We have an SR open, but crickets so far. Uncharacteristically long response time on this one.


Michael.Manuele
Nutanix Employee
Forum|alt.badge.img+4

What version of PC and can you share the SR#?


  • Voyager
  • 1 reply
  • April 28, 2022

same issue here after upgrading the AOS to 5.20.3.5 LTS. It’s ok with other cluster with 5.20.3 LTS so it seems to be related to the prism element and not to PC pc.2022.1.0.2.


Forum|alt.badge.img
  • Author
  • Adventurer
  • 8 replies
  • April 28, 2022

so far, the SE was thinking something is going on with Mercury on the PC cluster. We see this issue with every cluster we move to 5.20.3.5 LTS. One cluster was newer and shipped with 6, an it’s unaffected. PC v. 2022.10.2. Still waiting for his further analysis.


Forum|alt.badge.img
  • Author
  • Adventurer
  • 8 replies
  • April 29, 2022

sorry, PC 2022.1.0.2.


ThomasD
Forum|alt.badge.img+10
  • Trailblazer
  • 18 replies
  • May 2, 2022

Forum|alt.badge.img
  • Author
  • Adventurer
  • 8 replies
  • May 2, 2022

The SE went through, that, and it didn’t help. He said he was seeing some logs that pointed him to an issue with the mercury service. Waiting on an update.

 


Forum|alt.badge.img
  • Author
  • Adventurer
  • 8 replies
  • Answer
  • May 2, 2022

Got it!

Poked around some today. The various version folders on the PC nodes were missing the ‘console’ folder. KB 11663 gives a command to run to manually extract this. Once I did that on all the PC nodes, was again able to launch PE from PC.