We have the issue since Sunday that only some of the VMs power on after a scheduled Reboot via Citrix Studio (CVAD 1912 CU2). Of 9 Citrix VDA VMs only around 2-4 are starting each morning after receiving the power off and power on command via Citrix Studio for scheduled reboots.
When this issue happens the following event is showing on the Citrix Delivery Controller:
The description for Event ID 0 from source Nutanix VSS Software Provider cannot be found. Either the component that raises this event is not installed on your local computer or the installation is corrupted. You can install or repair the component on the local computer.
If the event originated on another computer, the display information had to be saved with the event.
The following information was included with the event:
Service started/resumed
Before and after this event other VMs can start without issue.
I dont see any error log on Nutanix / Prism when this happens. Only the Snapshot Events of the VMs.
When we test the Nutanix Hosting inside Citrix Studio all tests are successful.
What could be this issue? It did work without issues the weeks before and we didnt do any updates.
Nutanix Version pc.2022.6.0.1 with Nutanix AHV
Citrix Virtual Apps and Desktops 1912 CU2
Citrix Provisioning 1912 CU2
We already tried to separate the VMs in Citrix Studio that each VDA reboots at a different time with 30 minutes pause between via tagging and also tried the steps from this Article https://support.citrix.com/article/CTX237058/schedule-reboot-does-not-restart-machines-and-it-stays-in-shutdown-state