Can know impact of SSD failure if each node has 2 SSDs in slot0 & slot1:
1. Slot0 SSD failure
2. Slot1 SSD failure
3. Both SSDs failure (Know this will be CVM failure)
Solved
Impact of SSD failure
Best answer by patrbng
With 2 SSD's, if slot 0 fails the Cvm reboots and will recover using slot1, vm rights/reads flow to other nodes while Cvm is restarting. If slot 1 fails, no Cvm reboot occurs but SSD capacity is reduced, missing blocks are retrieved from other nodes as needed and re protected. If both SSD's fail, the Cvm is down and all read/writes are done to other nodes.