Solved

How to reset failed disk?

  • 3 October 2020
  • 2 replies
  • 1852 views

One of my physical disks failed because it had a loose connection in the drive bay. Where do I reset a flag for the failed disk or something similar that Nutanix tries again with the same disk?

(xpost: https://www.reddit.com/r/nutanix/comments/j4jl4f/how_to_reset_failed_disk/)

icon

Best answer by Ibinema 16 November 2020, 14:46

View original

This topic has been closed for comments

2 replies

Userlevel 2
Badge +4

Hi Ibinema,

 

When you re-seat the disk, it should automatically be added to the node and cluster.

If the disk still shows red, go to Prism → Hardware -->Diagram please click on the disk in question in and click on repartition and add.

 

Hope this helps,

 

Thank you

Get disk info:
- lsblk

Re-add as "failed" identified disk:
- ncli disk list-tombstone-entries
- ncli disk rm-tombstone-entry serial-number=*SERIAL*