- Use a Nutanix cluster external Data Services IP address when using IntelliSnap.
- Install a VSA on every Nutanix compute node.
- Install the MediaAgent software on all the VSA proxies.
- Install CommServe and MediaAgent on a secondary Nutanix cluster to separate backup and production infrastructure to protect against failure.
- Follow Commvault sizing guidelines.
- Create a virtual server client proxy group for easier management.
- When using IntelliSnap, colocate the MediaAgent software with the VSA.
- With ESXi, when you add ESX hosts to vCenter, make sure that the format of the ESX host name matches the host name format in vCenter. For example:
- If the host name format is short name, use short name to add the host to vCenter.
- If the host name format is FQDN, use FQDN to add the host to vCenter.
- If the host name is an IP address, use the same IP address to add the host to vCenter.
- With ESXi, use NBD as the transport mode whenever possible.
- With ESXi, configure the management network interfaces to use the 10 Gbps or faster NICs if available.
- With ESXi, follow current Nutanix vSphere networking recommendations.
- Ensure sufficient SSD space is available for the whole deduplication database when running MediaAgents as VMs for storage.
- Set up a seal schedule for the deduplication database by following Commvault’s documented process.
- If you’re using a Nutanix cluster as target storage, place MediaAgents and disk libraries on a separate secondary cluster.
- Use DASH full backups and the incremental forever approach for low-transaction VMs.
- Use IntelliSnap for high-transaction, high-SLA VMs.
- Don’t take more than one snapshot per container every hour.
- Thin-provision IntelliSnap VMs so they don’t consume additional space on restore.
- Keep IntelliSnap VMs on their own separate container.
- Limit VMs to 50 (or 3,200 files) on each IntelliSnap-protected container.
- Follow the protection domain limits as documented in Data Protection and Recovery with Prism Element.
- Make sure to apply the latest service packs and hotfixes from Commvault before deployment.
- When using Nutanix replication with IntelliSnap, offset the replication by at least one hour from the Commvault backup schedule.
For more information, please refer to portal documentation: https://portal.nutanix.com/page/documents/solutions/details?targetId=BP-2045-Commvault-with-Nutanix:top_best_practices_checklist.html