Does anyone know of a way to adjust the Gateway Timeout setting?
icon

Best answer by Roberteo 25 April 2019, 14:54

View original

This topic has been closed for comments

2 replies

Userlevel 2
Badge +3

Sorry for taking so long to get back to you. Yes, this is still happening but we have come up with a work around. The solution was to reduce the number of tests per 'round'. At this point, we perform a round of testing then circle back to re-run any failed tests. We then export the tests and delete them from X-Ray. The issue seems to be that too many test results (or maybe analysis) results in the error.

Userlevel 1
Badge +4
Hi Roberto,

Is this still happening? We should not need to change any settings for this to work.