Question

FATAL Imaging thread 'svm' failed with reason [none]

  • 16 November 2020
  • 12 replies
  • 779 views

Hi all,

I am trying to install Nutanix Community edition on a Hpe DL360 Gen 9 with the latest firmware.

This is the configuration:

256GB RAM
HPE Ethernet 1Gb 4-port 331i Adapter
Smart HBA H240 with:

  • 3x  1TB RAID 0 SSD for DATA DISK
  • 1x 1TB RAID 0 SSD for CVM Boot Disk
  • 1x USB Sandisk Ultra 3.0 for Hypervisor Boot

After selecting the discs after a few minutes I get this error:

Any ideas?

 

Thanks


12 replies

Hi Carlos,

 

I’m getting exactly the same error. Did you manage to find a fix/solution


Thanks​​​​​​​

Hi Mohideenyassarvm,

I have tried several installations but I have not found the solution. It seems that the installation is not so easy 

 

I’m trying to install this in a 4 Node server. 3 Nodes i was able to install Nutanix CE successfully. However only one node is giving this error. Difference between this node and other node is that the not working node has 4x1TB HDD, 1x400GB SSD and working nodes are having 3x1TB HDD , 1x400 GB HDD and 1x 400GB SSD

Thanks
Mohideen

 

 

Badge +1

I have the same error on my Intel NUC7

 

Intel NUC 7 i5 NUC7i5BNH, Intel Core i5-7260U with storage shown below (BIOS is current)

  • SanDisk - SDCZ430-016G-G46 16GB Ultra Fit USB 3.1 Flash Drive
  • 120 GB SSD Drive
  • Crucial P2 1TB 3D NAND NVMe
  • 40 GB Memory

 

Badge +1

To clarify, the “120 GB SSD Drive” is my SATA drive.

 

Badge +1

I am having exactly the same issue. Any ideas how to fix this?

Badge +1

For me it turns out it was an issue witht the RAID controller. I used the default PERC H710, which did not work. Swapping it for an LSI 2008 / 9211-8i made the difference.

Have this same issues with Dell R230 

4x 8TB on raid 5 

2x SSD 250GB 

in 60/2430 have always this error 

Any idea how to fix this ? IN other server install no have any problem 

Hello. I have the same issue. 

Any ideas to fix it?

I had this same problem on one of the 4 nodes in a Dell C6220II. The installer selected /dev/sdc as the CVM disk and /dev/sdd as the AHV disk. I wanted the AHV disk to be /dev/sdc and the CVM disk to be /dev/sdd, but every time I tried to modify during the install process, it would result in this particular error at around 420 or 450 out of 2430. When I accepted the default selection from the installer, it completed w/o error. I tested both SSDs successfully - both were perfectly operational, so not a disk problem. Very weird...

I had the same problem with installation ce-2020.09.16 on the Dell R730.

Before I was using the BIOS. But when I switched to EFI - 3 nodes were installed without any problems.

I have the same problem.

Any solution?