Have questions about how the Nutanix Platform works? Looking to get started - start here!
Most replies
When it comes to administering the Nutanix cluster, it's very important to control permissions and to restrict access to critical components such as CVMs, AHV hosts and the Prism UI. Any user that has write access to these components can make drastic changes to the Nutanix environment and thus to your organization’s production/testing environment. Here is how to reset the password for each of the components above: AHV | Root account password reset check out KB-7068 Reset Web Console or nCLI Password check out KB-1200 To recover CVM Password Through the Prism Web Console check out KB-2233
Want to know how to change the default credentials on the cluster? On Nutanix cluster’s if you have the default credentials you will receive an INFO message (default_password_check) in NCC health check informing you the same, you can change your CVM, Hypervisor and IPMI password using the guides below, you can also use script to change it on all nodes at once. Nutanix portal document
Although Prism is user friendly, it will be nice to know some commands that are useful for cluster management. Cluster status The cluster status or “cs | grep -v UP” command gives the status(up or down ) of all the CVMs and their services. Running this command is helpful when there are alerts in the prism about services being down on certain CVMs. Metadata ring The command “nodetool -h0 ring” shows if all the CVMs are a part of the metadata ring. Being in a metadata ring is essential for the CVM to be an active part of the cluster and handle its designated responsibilities. It is essential to run this command after every hardware replacement to make sure the node is back sharing responsibilities of the cluster. Health check Most of the problems in the cluster are easily diagnosed by the health check command “ncc health_checks run_all” At the end of every WARN/INFO/ERR/FAIL plug in we see a KB to further troubleshoot the issue. This check is essential to make sure if the cluster he
Below are new knowledge base articles published on the week of July 19-25, 2026.Support Portal login required:KB-17286 - LCM Restricted Mode: Upgrades are limited or blocked KB-21124 - Firmware manual upgrade collection KB-21725 - HPDX - LCM Inventory reports failure for nodes configured to be managed by OneView software KB-22123 - Configuring objects replication fails with "unable to get PC endpoints info across AZs" KB-22136 - NKP: TargetDown Alert for the grafana-logging job KB-22158 - NDB - Reports false clock synchronization errors after the NDB Server timezone is changed KB-22172 - Cerebro service unexpectedly terminates with 'Check failed: hypervisor_type == get<2>(*src_network_info)' after ESXi to AHV conversion KB-22199 - NX-G10: IPMI Active Directory authentication fails the WebUI config not populating DCs KB-22204 - Running atlas_cli commands in a Flow Standalone Mode enabled Prism Central KB-22208 - NX-8170A-G10 : BMC reports the M.2 temp sensor alert at 72C Threshold
Nutanix AHV is a bare metal Type-1 hypervisor developed by Nutanix. Nutanix AHV can be directly installed on any Nutanix certified OEM hardware server i.e SuperMicro NX, IBM CS , Lenovo HX , HPE ProLiant, Cisco UCS, Dell XC and many more being added along the way.AHV is built upon the CentOS KVM foundation and extends its base functionality to include features like HA and live migration, etc. Full hardware virtualization is used for guest VMs (HVM).In AHV deployments, the Controller VM (CVM) runs as a VM and disks are presented using PCI pass-through. This allows the full PCI controller (and attached devices) to be passed through directly to the CVM and bypass the hypervisor. AHV does not leverage a traditional storage stack like ESXi or Hyper-V. All disk(s) are passed to the VM(s) as raw SCSI block devices. This keeps the I/O path lightweight and optimized.KVM Architecture:Within KVM there are a few main components: KVM-kmod KVM kernel module Libvirtd An API, daemon and manag
Use these firewall requirements to configure rules in your external firewall to allow Nutanix Remote Support, Pulse, SMTP, 1-click upgrades, and LCM updates. Source Controller VM / Prism Central IP addresses Destination nsc01.nutanix.net and nsc02.nutanix.net Protocol - Port TCP - 80 and 8443 Action ALLOW Source Controller VM / Prism Central IP addresses Allows Pulse messages from the cluster to Nutanix support servers. Each Controller VM in your cluster collects Pulse configuration data continuously and sends Pulse metric data every 15 minutes to insights.nutanix.com over port 443 once every 15 minutes over HTTPS. Ports 80 and 8443 are the default ports that the cluster uses to connect to the Nutanix support servers nsc01.nutanix.net and nsc02.nutanix.net. Nutanix recommends that you open both ports. If one port is disabled, the cluster automatically tries to connect on the other. You can open the por
Hardware failures are a part of any datacenter lifecycle. The Nutanix architecture was designed with this inevitability in mind. A cluster can tolerate one or two failures (depending on the replication factor of the cluster or container) of a variety of hardware components while still running guest VMs and responding to commands through the management console. Many of these failures also trigger an alert through that same management console in order to give the administrator a chance to respond to the situation.Nutanix provides the ability to tolerate rack failures for extended data availability, in addition to drive, node, block, and network link failure.Block fault tolerance lets a Nutanix cluster make redundant copies of data and metadata and place the copies on nodes in different blocks.A block is a rack-mountable enclosure that contains one to four Nutanix nodes. All nodes in a block share power supplies, front control panels (ears), backplane, and fans.Nutanix offers block fault
Nutanix offers a monitoring & alerting utility, NCC - Nutanix Cluster check, which comes pre-installed on every CVM.Nutanix Cluster Check is a powerful framework which includes several plugins to monitor & alert on different hardware and software components. It is installed on every CVM across a single cluster on all nodes.It comes with almost all Nutanix products, such as Prism Central, Files etc. NCC will include the relevant checks for these products, enabling Nutanix administrators to keep on top of any software, configuration issues. Following are some of the important Hardware (Physical Components) checks and alerting offered byNCC:a) Periodic Disk checksb) Periodic BIOS / BMC Firmware checks (Versions / Upgrades required)c) Boot Devices Monitoring (Sata DOM or M.2)d) SSD and HDD wear and tear checkse) BIOS, BMC checks to ensure all hardware components are current and stablef) Network Interface card checksg) IPMI / Out of band management interface checksh) Power Supply
There are instances when you have to perform a rolling restart of the CVMs (Controller VMs) or a rolling restart of the hypervisor hosts or a restart of just one of the CVMs. This is a list of health checks to execute prior to the restart to verify cluster health. Verify if any nodes or services are in a 'down' state. Run the following command for smaller sized clusters: nutanix@cvm$ cluster status If the cluster contains multiple nodes, running the following command which excludes services that are UP from the output may be more convenient:nutanix@cvm$ cluster status | grep -v UPNodes or services that are unexpectedly in a 'down' state need to be fixed before proceeding with the restart. Verify if any nodes are missing or are in a 'down' state in the Cassandra ring. There should be the same number of nodes as the number of IPs in the svmips output (four nodes in the example below). If a node is missing, it means it was removed from the Cassandra ring:nutanix@cvm$ nodetool -h 0 ringAd
Let’s say you have Nutanix cluster with 24 CPU cores and 2 sockets and now you’re confused regarding the terminology. vCPU and cores per CPU and how to provision CPU to a Virtual Machine confusing you? Let’s break the terminology down in simple terms!In the world of Hardware, we have sockets and cores. In a host, there would be 2 sockets(or CPU) and 12 cores in each socket, resulting in 24 cores.So what is a vCPU?vCPU corresponds to the number of sockets for the VM. Cores per vCPU correspond to cores in a socket, so in conclusion, if you have provisioned your VM with the following configuration:2 vCPU 4 core per vCPUIn this scenario, your VM would have 2 sockets and 8 cores in total.How can I provision my vCPU, is there a guide or documentation regarding it?Absolutely yes, please give the following article a readCPU Configuration So is there a way to overprovision my CPU?Absolutely yes, please give the following article a readCPU Oversubscription
Let's say that you have 25 Gbps SFP+ Network card in your host and have created a Windows Virtual Machine with a 1 Gbps Nic card and now confused regarding the bandwidth for the virtual machine and how the Virtual Nic of the VM is different than the Host Nic when it comes to bandwidth and functionality. vNic is the software NIC emulation in the VM and is just a driver and in latest VMs the NIC is para-virtualised, which means that the NIC and Operating System is aware of the Host Physical NIC capability and understands that the vNic is just a driver. So what basically is this driver supposed to do? The vNic driver is really an API between the guest and the hypervisor so the vNic bandwidth is totally disconnected from any physical hardware. So what is the Physical NIC card then? Physical Nic is the physical network adapter connected to your physical switch and is responsible for the transfer of packets in your environment. So how Para virtualised vNic is better, does it have any advanta
Below are new knowledge base articles published on the week of September 13-19, 2020.KB 9982 - LCM: Operation failed. Reason: Multiple LAGs as uplinks in a VSwitch is not supported. KB 9987 - HPDX Platforms Cabling Guides KB 10004 - LCM inventory does not show available firmware updates for HPE nodes with iLO version 2019.03.01 KB 10008 - AHV | Uploading vhdx image may fail if the image is corrupted KB 10012 - Cloning an image and Updating disk size via Prism Element API V2 call KB 10014 - Unable to see option to edit existing disk settings for any VM in PC when logged in as Cluster/Prism Central Admin user KB 10026 - Move - Migration failed with Bad/incorrect request, AOS 5.18Note: You may need to log in to the Support Portal to view some of these articles.
Ever wondered what are some of the main services/components that make up Nutanix?The following is a simplified view of the main Nutanix cluster components.All components run on multiple nodes in the cluster and depend on connectivity between their peers that also run the same component. Cluster components ZeusKey Role: Access interface for Zookeeper· A key element of a distributed system, zeus is a method for all nodes to store and update the cluster's configuration. This zeus configuration includes details about the physical components in the cluster, such as hosts and disks, and logical components, like storage containers. The state of these components, including their IP addresses, capacities, and data replication rules, are also stored in the cluster configuration.· Zeus is the Nutanix library that all other components use to access the cluster configuration, which is currently implemented using Apache Zookeeper. MedusaKey role: Access interface for Cassandra· Distributed sy
To verify if we have replaced DIMM on correct slot and CPU we can use the following method We can look at hardware.history file which records any replacement for example DIMM,SSD,HDD,NIC being made to that node. This file remains local to each CVM After we replace DIMM we will boot the host up Power on CVM and run following command ncc hardware_info update_hardware_info This will update the hardware.history file present in ~/config directory and it will recognize any new replacement Open hardware.history using less less ~/config/hardware.history Go to last line by pressing shift+g Check out the most recent replacement it should look something like this Mon, 05 Oct 2020 15:37:01 CDT|Component changed: Memory module{locator:P1-DIMMC1} Old values: |{serial_number: 423D07AF}|(Last Detected Mon, 05 Oct 2020 10:13:25 CDT) New values: |{serial_number: 152057A5} It mentions DIMM P1-DIMMC1 was replaced and its serial number is changed from 423D07AF to 152057A5 This is a quick and
Already have an account? Login
Enter your E-mail address. We'll send you an e-mail with instructions to reset your password.