Installation & Configuration

Welcome to the Nutanix NEXT community. To get started please read our short welcome post. Thanks!

cancel
Showing results for 
Search instead for 
Did you mean: 

SCOM MP version 2 on Windows 2016 and SCOM 2016UR3

Highlighted
Wayfarer

SCOM MP version 2 on Windows 2016 and SCOM 2016UR3

Hi,

The install for the new MP (version2) asks at the beginning to check for port issues by running the ipmiutil command.

The following comes back....What ports are needed for this to work, is it just 443 and 623?

Also in the pevious MPs we had to select Authentication (SHA) and Privacy (AES) Protocols for the RunAs account. Are these not needed with this MP?

Thx,

John Bradshaw

-------------------------------------------------------

C:\Program Files\Nutanix Inc\SCOM\ipmiutil-3.0.2-win64>ipmiutil sensor -N 111.222.333.444 -U XXX -P YYY
ipmiutil ver 3.02
isensor: version 3.02
Connecting to node  111.222.333.444
ipmilan_open_session error, rv = -3
ipmilan receive from BMC failed
ipmi_open error = -3
ipmiutil sensor, receive from BMC failed

Tags (3)
3 REPLIES
Nutanix Employee

Re: SCOM MP version 2 on Windows 2016 and SCOM 2016UR3

For IPMI I believe UDP 623 is needed.   I don't believe the run as account configuration is needed for the 2.0 MP.

Tags (3)
Wayfarer

Re: SCOM MP version 2 on Windows 2016 and SCOM 2016UR3

Hi!

 

We have Nutanix with Dell XC hardware and we get exactly same ipmiutil error. Even locally run ipmiutil shows lots of errors on Dell XC hosts and exits before end.

 

=====
0056 GetSDR error 0xc5 Reservation ID cancelled or invalid, rlen=0
0057 GetSDR error 0xc5 Reservation ID cancelled or invalid, rlen=0
0057 SDR Comp 02 6f 20 a 29 snum 65 CMOS Battery     = 0000 OK
0058 GetSDR error 0xc5 Reservation ID cancelled or invalid, rlen=0
0059 GetSDR error 0xc5 Reservation ID cancelled or invalid, rlen=0
ipmiutil sensor, Reservation ID cancelled or invalid
====

 

All other our Dell servers show all ipmiutil sensor data corrctly and complete the task successfully.

 

BR
Jussi  

Wayfarer

Re: SCOM MP version 2 on Windows 2016 and SCOM 2016UR3

Nutanix MP seemingly works, but eg. "User VMs Overview" lists all "User VMs" names, total memory etc. correctly, but many VMs are missing CPU usage(%), Memory Usage(%) etc. information. No common factor which VMs work or not.

 

Also getting enormous amount of Operations Manager event warnings.

 

Event ID 11052
Module was unable to convert parameter to a double value
Original parameter: '$Data/Property[@Name='StoragePoolFreeStorage']$'
Parameter after $Data replacement: '17 944,71'
Error: 0x80020005
Details: Type mismatch.


Event ID 31876
Data item returned no information for parameter '$Data/Property[@Name='ClusterIP']$'
This usually indicates that the query is incorrect.